RFL SMX3 / 21 Page 9 of 22 Issue 1.4
User Manual
08 June 2009
Standard Concatenation Port Pin-out (DTE configuration)
as used for Aggregate Concatenation - D15F on chassis
Circuit Pin A Pin B Direction Notes
T Transmit Data 2 9 Output
R Receive Data 4 11 Input
S Signal Element
Timing
6 13 Input Timing signal derived from the
network
G Ground 8 15
X Signal Element
Timing
7 14 Output Timing signal derived from the
port and transmitted to network.
C Control 3 10 Output Permanently on. Not used in
Aggregate Concatenation
I Indication 5 12 Input Signal ignored. Not used in
Aggregate Concatenation
Screen / Drain
Must be earthed to shell
Aggregate Concatenation to a co-located SMX3/21 requires a five twisted pair cross-
over cable with overall shield (eg RS 111-8988). Maximum recommended length
10m (check Utility standards).
Aggregate Concatenation Cable
D15M – D15M
Pair Pin End 1 End 2
A 2 4
1
B 9 11
A 4 2
2
B 11 9
A 6 7
3
B 13 14
A 7 6
4
B 14 13
A 8 8
5
B 15 15
Screen / Drain
Must be earthed to
connector shells at
both ends
The following table is for information only, and is not used in any standard configurations.
Optional Concatenation Port Pin-out (when in DCE configuration) – D15F on chassis
Circuit Pin A Pin B Direction Notes
T Transmit Data 2 9 Input
R Receive Data 4 11 Output
C Control 3 10 Input Signal ignored
I Indication 5 12 Output Permanently on
S Signal Element
Timing
6 13 Output Timing signal derived from
the port and transmitted to
network
G Ground 8 15
Screen / Drain
Must be earthed to shell