Page B–8
FOCUS System Manual
No Settings Mismatch CLEARED
Returned to normal
Information Settings restored from flash of %s %d
MM flash memory copy of settings copied to program memory, %s %d = date config. locked
Yes Standby Power Supply Failure
Standby Power Supply was not detected by Maint. Module, and one is present
No Standby Power Supply Failure CLEARED
Returned to normal
Yes T
ransceiver 1 Failure
Transceiver 1 was not detected by MM, and one was present when chassis was locked
No T
ransceiver 1 Failure CLEARED
Returned to normal
Yes Transceiver 2 Failure
Transceiver 2 was not detected by MM, and one was present when chassis was locked
No T
ransceiver 2 Failure CLEARED
Returned to normal
Yes Yellow Alarm On
Remote FOCUS is not receiving transmitted signal from local FOCUS
No Y
ellow Alarm On CLEARED
Returned to normal
ALARM, EVENT TEXT
,CONT’D
CONCERN? EXPLANATION OF EVENT